Aller au contenu principal
1/5

PEACEFAIR PZEM-017 Module de Mesure d'Énergie CC pour Surveillance de Puissance et Tension

24,99€
Produit similaire livré par
KETLER - KE8003 : Compteur électrique - Monophasé 80 A - Remise à zéro partielle - Sortie d'impulsion - Simple tarif
KETLER - KE8003 : Compteur électrique - Monophasé 80 A - Remise à zéro partielle - Sortie d'impulsion - Simple tarif
29,67 €
214

Ces articles peuvent vous intéresser !

Comparer à des articles similaires

Informations produit

Description

1、It is mainly used for measuring DC voltage, current, active power, frequency and energy consumption

2、The current measure range is 50A, 100A, 200A, 300A depend on the external shunt specification

3、There are 10 different kits to choose, enough to meet your various need

4、Physical layer use UART to RS485 communication interface, baud rate is 9600, 8 data bits, 2 stop bit, no parity

5、The application layer use the ModbusRTU protocol to communicate, it only supports function codes such as 0x03, 0x04,0x06, 0x41, 0x42, etc

This module is mainly used for measuring DC voltage, current, active power, frequency and energy consumption, the module is without display function, the data is read through the RS485 interface.

Features:

It is mainly used for measuring DC voltage, current, active power, frequency and energy consumption.

The current measure range is 50A, 100A, 200A, 300A depend on the external shunt specification.

There are 10 different kits to choose, enough to meet your various need.

Physical layer use UART to RS485 communication interface, baud rate is 9600, 8 data bits, 2 stop bit, no parity.

The application layer use the ModbusRTU protocol to communicate, it only supports function codes such as 0x03, 0x04,0x06, 0x41, 0x42, etc.

Voltage threshold can be set, divide into high voltage and low voltage threshold, when the measured voltage exceeds the threshold, it can alarm.

Specification:

Brand: PEACEFAIR

Model: PZEM-017

Voltage:

Measuring Range: 0.05-300V (When the test voltage is <7V, please use the independent power supply mode)

Resolution: 0.01V

Measurement Accuracy: 1%

Current:

Measuring Range: 0.02-300A (Can be matched with 50A, 100A, 200A, 300A four kinds of shunt)

Resolution: 0.01A

Measurement Accuracy: 1%

Power:

Measuring Range: 0.2-90kW

Resolution: 0.1W

Measurement Accuracy: 1%

Energy Consumption:

Measuring Range:0-9999kWh

Resolution: 1Wh

Measurement Accuracy: 1%

Reset Energy: Use Software to Reset

Over Voltage Alarm:

Default High Voltage Threshold: 300V

Default Low Voltage Threshold: 7V

Communication Interface: RS485 Interface

Working Temperature: -20~60℃

Product Size: Approx. 9*6*2.3cm/3.5*2.4*0.9inch

Weight: Approx. 77g~287g / 2.7oz~10.1oz

Register address

Description

Resolution

0x0000

Voltage value

1LSB correspond to 0.01V

0x0001

Current value

1LSB correspond to 0.01A

0x0002

Power value low 16 bits

1LSB correspond to 0.1W

0x0003

Power value high 16 bits

0x0004

Energy value low 16 bits

1LSB correspond to 1Wh

0x0005

Energy value high 16 bits

0x0006

High voltage alarm status

0xFFFF is alarm,0x0000 is not alarm

0x0007

Low voltage alarm status

0xFFFF is alarm,0x0000 is not alarm

Register address

Description

Resolution

0x0000

High voltage alarm

threshold(5~350V),

default is 300V

1LSB correspond to 0.01V

0x0001

Low voltage alarm

threshold(1~350V),

default is 7V

1LSB correspond to 0.01V

0x0002

Modbus-RTU address

The range is

0x0001~0x00F7

0x0003

The current range

0x0000: 100A

0x0001: 50A

0x0002: 200A

0x0003: 300A

Optional

Kit

#1

1 x DC Consumption Meter

#2

1 x DC Consumption Meter

1 x RS485 to USB Cable

#3

1 x DC Consumption Meter

1 x 50A Shunt

#4

1 x DC Consumption Meter

1 x 100A Shunt

#5

1 x DC Consumption Meter

1 x 200A Shunt

#6

1 x DC Consumption Meter

1 x 300A Shunt

#7

1 x DC Consumption Meter

1 x RS485 to USB Cable

1 x 50A Shunt

#8

1 x DC Consumption Meter

1 x RS485 to USB Cable

1 x 100A Shunt

#9

1 x DC Consumption Meter

1 x RS485 to USB Cable

1 x 200A Shunt

#10

1 x DC Consumption Meter

1 x RS485 to USB Cable

1 x 300A Shunt

Note:

  1. RS485 interface is passive output, need external connect 5V power supply and the external power supply should >100mA.

    When the input test voltage is less than 7V, it must supply 5V independent work voltage through USB port.

    Do NOT use the USB port bring by your PC to be the independent power supply, otherwise it may damage your PC.

Caractéristiques

  • Marque
    RDTD
  • Fonction de pilotage
    Non
  • Matières
    Plastique
  • Nombre de module(s)
    1
  • Nombre de sortie(s)
    1
  • Type de compteur
    Électricité
  • Réf. ManoMano
    ME211193226
  • MMID
    326196513327
  • Réf. fabricant
    LHL0409-YM13802
  • EAN
    1252968639337
Conseil par

Comment choisir son indicateur de consommation d'énergie

La consommation totale d'énergie d'une installation se mesure grâce aux compteurs d'électricité et de gaz. Convertir des m³ de gaz en kWh n'a rien d'évident, pas plus que de savoir à quoi cette énergie été destinée. Un indicateur d'énergie peut vous rendre ces services.
Comment choisir son indicateur de consommation d'énergie
Vous êtes ici :
Le spécialiste français du bricolage, maison, jardin

Le spécialiste français du bricolage, maison, jardin

Livraison et retours gratuits pendant 100 jours avec ManoExpress. ,[object Object]

Livraison et retours gratuits pendant 100 jours avec ManoExpress. En savoir plus

Paiement jusqu'à 12x par carte bancaire avec Alma. ,[object Object]

Paiement jusqu'à 12x par carte bancaire avec Alma. En savoir plus

Plus de 7 millions de clients pros et particuliers

Plus de 7 millions de clients pros et particuliers