Thermocouple Honeywell Q309A2788 900 mm
Vous achetez pour votre entreprise ?
Tarifs négociés HT jusqu'à -20%
Vendu par Le sanitaire
Ces articles peuvent vous intéresser !
Comparer à des articles similaires
Souvent achetés ensemble
Informations produit
Description
The thermocouple has been developed for the use with different pilot burners. As long as the pilot flame heats the tip of the thermocouple, a low DC voltage is generated which supplies the coil of the safety pilot and keeps the safety valve open. If in case of a failure the pilot flame goes out, no voltage is generated any more and the safety pilot interrupts the gas supply to the burner.Technical data:- DC voltage: 22...30 mV- max. drop-out time: 30 or 45 s (depending on the order number)- max. operating temperature: hot junction: 750° C / cold junction: 415° C- recommended operating temperature: hot junction: 650° C +/- 50° C
Caractéristiques
- MarqueLE SANITAIRE
- Garantie1 an(s)
- Longueur900 mm
- MatièresCuivre
- Réf. ManoManoME33230587
- MMID300591843134
- Réf. fabricantSAN133404108
- EAN8714724005082
Questions fréquentes
Quelle est la plage de tension continue générée par cet équipement ?
Cet équipement génère une tension continue dans une plage de 22 à 30 mV lorsque la flamme pilote chauffe l'extrémité du thermocouple.
Quelle est la température maximale de fonctionnement pour la jonction chaude ?
La température maximale de fonctionnement pour la jonction chaude est de 750 °C.
Quel est le temps maximum de coupure en cas de défaillance de la flamme pilote ?
Le temps maximum de coupure en cas de défaillance de la flamme pilote est de 30 ou 45 secondes, selon le numéro de commande.