Aller au contenu principal
1/5

Rain and Snow Sensor Module Snow Raindrops Detection Sensor 485 Mode Automatic Heating 10‑30V

(38,99€/pc)
47,99€

Informations produit

Description

1、Main Function: The rain and snow sensor is a qualitative measuring device for measuring whether it rains or snows outdoors or in nature. The measurement of rain and snow, the response time is less than or equal to 0.5S.

2、High Sensitivity: The unique AC measurement technology prevents oxidation reacting of the induction plate and ensures longterm sensitivity. The sensitivity of the sensor is adjustable, making it more flexible to use.

3、Automatic Heating: Optional automatic heating function can be used for snow detection to prevent freezing and condensation in situations where the temperature is lower than 0 degrees for a long time and high humidity.

4、Strict Temperature Control: The temperature during heating is strictly controlled within 40 ℃ (default) to prevent over oxidation caused by dry burning and prolong the service life.

5、Protection Function: IP68 protection grade design, can work outdoors for a long time. Alarm and reset delay can be set to avoid frequent on site alarms. It is safe and reliable, beautiful in appearance and easy to install.

Item Type: Rain and Snow Sensor

Material: Plastic

Weight: Approx. 153g/5.40oz

Size: 89x64x38mm/3.50x2.52x1.50in

Power Supply: 10-30V DC

Normal Working Power:0.4W

Storage Environment:-40℃-80℃

Output Signal: 485

Parameter Configuration: Software setting

Default Address: 01

Support Function Code: 03, 06

Maximum Heating Temperature: 40℃

Output Relay With Load Capacity: 250VAC 1A, 30VDC 1A

Product Model: RS YUX N01 H

Product Type: 485 mode, automatic heating

Wire Sequence: VCC(brown) GND(black) A(yellow) B(blue)

Ambient Temperature For Heating Start: <15°C (default)

Maximum Heating Temperature: 40℃(default)

Working Power When Heating:2.4W

Application: It can be widely used in the qualitative measurement of the presence or absence of rain and snow in the environment, greenhouses, breeding, buildings, buildings, etc.

Wiring Instructions: Voltage power input can be 10~30V. When wiring the 485 signal line, pay attention to the two lines A B not to be reversed, and the addresses of multiple devices on the bus must not conflict.

Power: Positive power supply (10-30V DC) (brown), Power negative (black)

Output: 485 A(yellow), 485 B(blue)

Possible reason that device cannot connect to the PLC or computer:

1) The computer has multiple COM ports, and the selected port is incorrect.

2) The device address is wrong, or there are devices with duplicate addresses (the factory defaults are all 1).

3) The baud rate, check method, data bit, stop bit are wrong.

4) The host polling interval and waiting response time are too short, and both need to be set above 200ms.

5) The 485 bus is disconnected, or the A and B wires are connected reversely.

6) If the number of equipment is too much or the wiring is too long, power supply should be nearby, add a 485 booster, and add a 120Ω terminal resistance.

7) The USB to 485 driver is not installed or damaged.

8) The equipment is damaged.

Description of alarm reset delay setting

If this value is set to 10S, the device will consider the device to detect rain and snow and output an alarm state if the duration of rain and snow detected exceeds 10S, and if the duration of rain and snow detected is less than 10S, the device will consider it not detected To rain and snow; the same is true when rain and snow return to normal.

Default value: 1 second

Range: 0-60000 seconds

Sensitivity setting description:

The sensitivity value is inversely proportional to the actual sensitivity. The larger the set value, the less sensitive the device detection, and the smaller the sensitivity value, the more sensitive the device detection. But it should be noted that if the sensitivity value is too small, it is easy to cause false alarms. It is recommended to use the factory default value.

Default value: 800

Range: 500-3500

Data frame format definition

Using RTU communication protocol, the format is as follows:

Initial structure ≥ 4 bytes of time

Address code = 1 byte

Function code = 1 byte

Data area = N bytes

Error check = 16-bit CRC code

Time to end structure ≥ 4 bytes

Address code: the address of the transmitter, which is unique in the communication network (factory default 0x01).

Function code: The command function instruction issued by the host, this transmitter only uses function codes 0x03 and 0x06.

Data area: The data area is the specific communication data, pay attention to the high byte of the 16bits data first!

CRC code: two byte check code.

4 x Expansion Plug

4 x Self Tapping Screw

1 x Sensor

1 x Instruction

Caractéristiques

  • Marque
    SABE
  • Couleur
    Multicouleur
  • Indice de protection
    IP68
  • Matières
    Plastique
  • Réf. ManoMano
    ME235596957
  • MMID
    357346366358
  • Réf. fabricant
    SABE0810-FX02305
  • EAN
    7551847550386
Conseil par

Comment choisir une alarme

Si l'on s'équipe souvent d'une alarme anti-intrusion ou de détecteurs de fumée, on pense moins souvent aux autres détecteurs, qu'ils soient autonomes ou à relier à une centrale d'alarme. Détecteurs de chaleur, de gaz, d'inondation améliorent la sécurité des personnes et des biens pour votre plus grande tranquillité.
Comment choisir une alarme
Vous êtes ici :
Le spécialiste français du bricolage, maison, jardin

Le spécialiste français du bricolage, maison, jardin

Livraison et retours gratuits pendant 100 jours avec ManoExpress. ,[object Object]