Câble monoconducteur en FEP homologué VDE Sec. 0,25 mmq Noir
Produit similaire livré par
Festool – Câble plug it H05 RN-F/4 – Longueur 4 m – Section 1,5 mm² – 4 fils – 203914
28,42 €
180
Vendu par Errebi shop
Ces articles peuvent vous intéresser !
Comparer à des articles similaires
Souvent achetés ensemble
Informations produit
Description
Code ErreBi: 48868
Vendu au mètre
Prix au 5 mètres
correspond à 5 mètres
Exemple: Si vous achetez 3 quantités, vous recevrez une pièce unique de 15 mètres
CONDITIONS OF USE
To be used for fixed internal wiring of electrical equipment or lamps where the temperature on the conductor is not higher than the maximum permissible temperature. Installation in pipes, ducts or conduits is permitted.
TECHNICAL CHARACTERISTICS
Test voltage: 2000 V
Nominal voltage: 450/750 V
VDE: Reg. Nos. 7027, 7909
Short circuit temperature: 300°C
Operating temperature: 180°C, 200°C or 250°C
Minimum bending radius: 12 x D
Flame resistance: IEC 60332-1-2
Suitable for internal installation
Suitable for fixed installation
APPLICATIONS
VDE approved single-core flexible cable for high temperatures with
FEP insulation, suitable for internal wiring of electrical
equipment and lighting with a maximum conductor temperature
of 180 °C. Excellent resistance to industrial oils, exposure to
ozone and UV as well as to a wide range of chemical
substances
Scheda Tecnica
Type de produit: Câble FEP
Couleur: Noir
Diamètre externe: 1.10 mm
Voltage: 450/750V
Température de fonctionnement min.: -55°C
Température de fonctionnement max.: +180°C
Matériau d'isolation: Fluorure de Propylène et d'Ethylène (FEP)
Conducteur (matériel): Cuivre
Section de câble mmq: 0.25 mmq
Section de câble AWG: 18 AWG - 22 AWG
Blindage: Non
Test de tension: 2000V
Résistance à la flamme: CEI 60332-1-2
Type d'emploi: Câblage Interne
Résistance du conducteur: <= 86.0 Ohm/Km
Vendu au mètre
Prix au 5 mètres
correspond à 5 mètres
Exemple: Si vous achetez 3 quantités, vous recevrez une pièce unique de 15 mètres
CONDITIONS OF USE
To be used for fixed internal wiring of electrical equipment or lamps where the temperature on the conductor is not higher than the maximum permissible temperature. Installation in pipes, ducts or conduits is permitted.
TECHNICAL CHARACTERISTICS
Test voltage: 2000 V
Nominal voltage: 450/750 V
VDE: Reg. Nos. 7027, 7909
Short circuit temperature: 300°C
Operating temperature: 180°C, 200°C or 250°C
Minimum bending radius: 12 x D
Flame resistance: IEC 60332-1-2
Suitable for internal installation
Suitable for fixed installation
APPLICATIONS
VDE approved single-core flexible cable for high temperatures with
FEP insulation, suitable for internal wiring of electrical
equipment and lighting with a maximum conductor temperature
of 180 °C. Excellent resistance to industrial oils, exposure to
ozone and UV as well as to a wide range of chemical
substances
Scheda Tecnica
Type de produit: Câble FEP
Couleur: Noir
Diamètre externe: 1.10 mm
Voltage: 450/750V
Température de fonctionnement min.: -55°C
Température de fonctionnement max.: +180°C
Matériau d'isolation: Fluorure de Propylène et d'Ethylène (FEP)
Conducteur (matériel): Cuivre
Section de câble mmq: 0.25 mmq
Section de câble AWG: 18 AWG - 22 AWG
Blindage: Non
Test de tension: 2000V
Résistance à la flamme: CEI 60332-1-2
Type d'emploi: Câblage Interne
Résistance du conducteur: <= 86.0 Ohm/Km
Caractéristiques
- MarqueERREBI GROUP
- Longueur5 m
- Poids50 g
- MatièresCuivre
- CouleurNoir
Questions fréquentes
Ce câble peut supporter une température de fonctionnement maximale de 180°C.
Oui, ce câble est conçu pour une installation fixe et est approprié pour un câblage interne.
Ce câble présente une résistance à la flamme conforme à la norme CEI 60332-1-2.
Réponses générées par IA à partir des informations vendeur
Conseil par
Comment choisir des fils et câbles électriques ?
La section des fils électriques et des câbles est fonction de l’intensité, de l’installation et des équipements. Fil 3G1.5mm², fil monobrin, câblette, fil coaxial, connectique RJ45 ou fil hifi, la famille est nombreuse ! Pour ne plus confondre la phase, le neutre et la terre : suivez le guide !