Nominal voltage Uo/U: 450/750 V
Maximum operating temperature: 70°C
Minimum operating temperature: -10°C (without mechanical stress)
Minimum installation temperature: 5°C
Maximum short circuit temperature: 160°C
Maximum tensile stress: 50 N/mm2
Minimum bending radius: 4 x maximum external diameter
Use and installation
For systems requiring not propagating fire cables.
For installation in surface conduits or embedded conduits or similar closed systems.
Suitable for fixed and protected installation in lighting appliances and switching and control equipments, allowed for voltages up to 1000 V a.c. or up to 750 V d.c. to ground.
The 1 mm² section is provided (in addition to others) only for internal wiring in switchboards for signalling and control or for electric circuits of lifts and hoists.
For fire risk installations, the maximum temperature must not exceed 55°C. (ref. CEI 20-40)
Vendu au mètre
Prix au 2 mètres
correspond à 2 mètres
Exemple: Si vous achetez 3 quantités, vous recevrez une pièce unique de 6 mètres
Nominal voltage Uo/U: 450/750 V
Maximum operating temperature: 70°C
Minimum operating temperature: -10°C (without mechanical stress)
Minimum installation temperature: 5°C
Maximum short circuit temperature: 160°C
Maximum tensile stress: 50 N/mm2
Minimum bending radius: 4 x maximum external diameter
Use and installation
For systems requiring not propagating fire cables.
For installation in surface conduits or embedded conduits or similar closed systems.
Suitable for fixed and protected installation in lighting appliances and switching and control equipments, allowed for voltages up to 1000 V a.c. or up to 750 V d.c. to ground.
The 1 mm² section is provided (in addition to others) only for internal wiring in switchboards for signalling and control or for electric circuits of lifts and hoists.
For fire risk installations, the maximum temperature must not exceed 55°C. (ref. CEI 20-40)
Caractéristiques
- MarqueERREBI GROUP
- CouleurBlanc / Rouge
- Section2.5 mm²
- Poids60 g
- Quantité par pack2
- MatièresCuivre
- Type de câble électriqueUnipolaire
- Réf. ManoManoME11332609
- MMID482115837410
- Réf. fabricantRBCV2.5N07BNRO
Questions fréquentes
Quelle est la température maximale que ce câble peut supporter en cas de court-circuit ?
Ce câble peut supporter une température maximale de 160°C en cas de court-circuit.
Ce câble peut-il être utilisé dans des installations soumises à des risques d'incendie ?
Oui, ce câble peut être utilisé dans des installations soumises à des risques d'incendie, mais la température maximale ne doit pas dépasser 55°C dans ces conditions.
Quelle est la contrainte minimale de courbure pour l'installation de ce câble ?