Ces articles peuvent vous intéresser !
Comparer à des articles similaires
Souvent achetés ensemble
Informations produit
Description
Code ErreBi: 48681
Vendu au mètre
Nominal voltage Uo/U: 450/750 V
Maximum operating temperature: 70°C
Minimum operating temperature: -10°C (without mechanical stress)
Minimum installation temperature: 5°C
Maximum short circuit temperature: 160°C
Maximum tensile stress: 50 N/mm2
Minimum bending radius: 4 x maximum external diameter
Use and installation
For systems requiring not propagating fire cables.
For installation in surface conduits or embedded conduits or similar closed systems.
Suitable for fixed and protected installation in lighting appliances and switching and control equipments, allowed for voltages up to 1000 V a.c. or up to 750 V d.c. to ground.
The 1 mm² section is provided (in addition to others) only for internal wiring in switchboards for signalling and control or for electric circuits of lifts and hoists.
For fire risk installations, the maximum temperature must not exceed 55°C. (ref. CEI 20-40)
Scheda Tecnica
Type de produit: Câble H07V-K
Couleur: Noir
Diamètre externe: 9.00 mm
Voltage: 750V
Température de fonctionnement min.: -10°C
Température de fonctionnement max.: +70°C
Matériau d'isolation: PVC
Conducteur (matériel): Cuivre Electrolytique
Section de câble mmq: 25.00 mmq
Blindage: Non
Test de tension: 2500V
Type d'emploi: Câblage Interne
Résistance du conducteur: <= 0.780 Ohm/Km
Vendu au mètre
Nominal voltage Uo/U: 450/750 V
Maximum operating temperature: 70°C
Minimum operating temperature: -10°C (without mechanical stress)
Minimum installation temperature: 5°C
Maximum short circuit temperature: 160°C
Maximum tensile stress: 50 N/mm2
Minimum bending radius: 4 x maximum external diameter
Use and installation
For systems requiring not propagating fire cables.
For installation in surface conduits or embedded conduits or similar closed systems.
Suitable for fixed and protected installation in lighting appliances and switching and control equipments, allowed for voltages up to 1000 V a.c. or up to 750 V d.c. to ground.
The 1 mm² section is provided (in addition to others) only for internal wiring in switchboards for signalling and control or for electric circuits of lifts and hoists.
For fire risk installations, the maximum temperature must not exceed 55°C. (ref. CEI 20-40)
Scheda Tecnica
Type de produit: Câble H07V-K
Couleur: Noir
Diamètre externe: 9.00 mm
Voltage: 750V
Température de fonctionnement min.: -10°C
Température de fonctionnement max.: +70°C
Matériau d'isolation: PVC
Conducteur (matériel): Cuivre Electrolytique
Section de câble mmq: 25.00 mmq
Blindage: Non
Test de tension: 2500V
Type d'emploi: Câblage Interne
Résistance du conducteur: <= 0.780 Ohm/Km
Caractéristiques
- MarqueERREBI GROUP
- CouleurNoir
- Section25 mm²
- Poids240 g
- Quantité par pack1
- Isolation du filPVC
- Longueur du câble électrique100 cm
- MatièresPVC
- Type de câble électriqueUnipolaire
- Réf. ManoManoME40887192
- MMID577096683465
- Réf. fabricantRBCV25N07GR
Questions fréquentes
La température maximale de fonctionnement pour ce type de câble est de 70°C.
Le rayon de courbure minimum requis lors de l'installation est de 4 fois le diamètre externe maximum.
Oui, ce câble est conçu pour des systèmes nécessitant des câbles non propagateurs de feu, mais la température maximale ne doit pas dépasser 55°C dans ces installations.
Réponses générées par IA à partir des informations vendeur
Conseil par
Comment choisir des fils et câbles électriques ?
La section des fils électriques et des câbles est fonction de l’intensité, de l’installation et des équipements. Fil 3G1.5mm², fil monobrin, câblette, fil coaxial, connectique RJ45 ou fil hifi, la famille est nombreuse ! Pour ne plus confondre la phase, le neutre et la terre : suivez le guide !
Vous êtes ici :