Câble Fil Unipolaire H05V-K sec. 0,35 mmq Marron/Bleu
Produit similaire livré par
Festool – Câble plug it H05 RN-F/4 – Longueur 4 m – Section 1,5 mm² – 4 fils – 203914
28,42 €
180
Vendu par Errebi shop
Ces articles peuvent vous intéresser !
Comparer à des articles similaires
Informations produit
Description
Code ErreBi: 66376
Vendu au mètre
Nominal voltage Uo/U: 300/500 V
Maximum operating temperature: 70°C
Minimum operating temperature: -10°C (without mechanical stress)
Minimum installation temperature: 5°C
Maximum short circuit temperature: 160°C
Maximum tensile stress: 50 N/mm2
Minimum bending radius: 4 x maximum external diameter
Use and installation
For systems requiring not propagating fire cables. For installation in surface conduits or embedded conduits or similar closed systems. Suitable for fixed and protected installation in lighting appliances and switching and control equipments, allowed for voltages up to 1000 V a.c. or up to 750 V d.c. to ground. The 1 mm² section is provided (in addition to others) only for internal wiring in switchboards for signalling and control or for electric circuits of lifts and hoists. For fire risk installations, the maximum temperature must not exceed 55°C. (ref. CEI 20-40)
Scheda Tecnica
Type de produit: Câble H05V-K
Couleur: Marron/Bleu
Diamètre externe: 1.60 mm
Voltage: 300/500V
Température de fonctionnement min.: -10°C
Température de fonctionnement max.: +70°C
Matériau d'isolation: PVC
Conducteur (matériel): Cuivre Electrolytique
Section de câble mmq: 0.35 mmq
Blindage: Non
Test de tension: 2500V
Type d'emploi: Câblage Interne
Vendu au mètre
Nominal voltage Uo/U: 300/500 V
Maximum operating temperature: 70°C
Minimum operating temperature: -10°C (without mechanical stress)
Minimum installation temperature: 5°C
Maximum short circuit temperature: 160°C
Maximum tensile stress: 50 N/mm2
Minimum bending radius: 4 x maximum external diameter
Use and installation
For systems requiring not propagating fire cables. For installation in surface conduits or embedded conduits or similar closed systems. Suitable for fixed and protected installation in lighting appliances and switching and control equipments, allowed for voltages up to 1000 V a.c. or up to 750 V d.c. to ground. The 1 mm² section is provided (in addition to others) only for internal wiring in switchboards for signalling and control or for electric circuits of lifts and hoists. For fire risk installations, the maximum temperature must not exceed 55°C. (ref. CEI 20-40)
Scheda Tecnica
Type de produit: Câble H05V-K
Couleur: Marron/Bleu
Diamètre externe: 1.60 mm
Voltage: 300/500V
Température de fonctionnement min.: -10°C
Température de fonctionnement max.: +70°C
Matériau d'isolation: PVC
Conducteur (matériel): Cuivre Electrolytique
Section de câble mmq: 0.35 mmq
Blindage: Non
Test de tension: 2500V
Type d'emploi: Câblage Interne
Caractéristiques
- MarqueERREBI GROUP
- Longueur1 m
- MatièresPVC
- CouleurBleu / Marron
- Quantité par pack1
Questions fréquentes
La température de fonctionnement maximale pour ce type de câble est de 70°C. Cependant, pour les installations à risque d'incendie, il est recommandé de ne pas dépasser 55°C.
Oui, ce câble est conçu pour être installé dans des conduits de surface ou des conduits encastrés, ce qui le rend adapté à des installations fixes et protégées.
Ce câble peut supporter une tension nominale allant jusqu'à 450/750 V, ce qui le rend approprié pour des applications électriques internes.
Réponses générées par IA à partir des informations vendeur
Conseil par
Comment choisir des fils et câbles électriques ?
La section des fils électriques et des câbles est fonction de l’intensité, de l’installation et des équipements. Fil 3G1.5mm², fil monobrin, câblette, fil coaxial, connectique RJ45 ou fil hifi, la famille est nombreuse ! Pour ne plus confondre la phase, le neutre et la terre : suivez le guide !
Vous êtes ici :