Câble Fil Unipolaire FLRY-B ISO 6722 Classe B Sec. 2,50 mmq Vert
Produit similaire livré par
Câble plug it FESTOOL H05 RN-F4/3 – Longueur 4 m – Section 3G1.5 mm² – Pour outils avec système plug-it
45,06 €
186
Vendu par Errebi shop
Ces articles peuvent vous intéresser !
Comparer à des articles similaires
Souvent achetés ensemble
Informations produit
Description
Code ErreBi: 25973
Vendu au mètre
APPLICATIONS
PVC insulated flexible single core cables that is intended for use on low voltage electrical installations, systems and components of road vehicles where the heat exposure is not continuous on cable surface The FR125 F5 cables are mainly intended for the wiring everywhere a frequent thermal loading, but continuously on cable, could be occurred.
CABLE STRUCTURE
1. Flexible electrolytic bare copper conductor: stranded multi-wire
2. Type B and class T2 105°C rated PVC insulation
Temperature range: -40 to 105°C (fixed)
Short-circuit temperature: 160°C
Voltage: 220 V. c.a. 300 V. c.c.
Test voltage: 3 kV AC (<= 0.50 mmq), 5 kV AC (> 0.50 mmq)
Flame resistance: DIN 72551 Part 5, 7.Z8220, Par. 3.7
Bending radius: >= 6 x D (fixed)
Suitable for indoor use
Suitable for fixed installation
Resistance to chemical agents: DIN 72551 Part 5, ISO 6722, 7.Z8220 Par. 3.8
Resistance to diesel and gasoline: ISO 6722, 7.Z8220 Par. 3.8
Resistance to engine oil: ISO 6722 (ISO 1817 oil No. 3), 7.Z8220, Par. 3.8 (Class O1 oil)
Scheda Tecnica
Type de produit: FLRY-B Câble
Couleur: Vert
Diamètre externe: 2.90 mm
Voltage: 50V
Température de fonctionnement min.: -40°C
Température de fonctionnement max.: +105°C
Matériau d'isolation: PVC
Conducteur (matériel): Cuivre rouge
Section de câble mmq: 2.50 mmq
Nombre de brins: 50
Blindage: Non
Test de tension: 5000V
Type d'emploi: Secteur Automobile
Résistance du conducteur: <= 7.6 Ohm/Km
Vendu au mètre
APPLICATIONS
PVC insulated flexible single core cables that is intended for use on low voltage electrical installations, systems and components of road vehicles where the heat exposure is not continuous on cable surface The FR125 F5 cables are mainly intended for the wiring everywhere a frequent thermal loading, but continuously on cable, could be occurred.
CABLE STRUCTURE
1. Flexible electrolytic bare copper conductor: stranded multi-wire
2. Type B and class T2 105°C rated PVC insulation
Temperature range: -40 to 105°C (fixed)
Short-circuit temperature: 160°C
Voltage: 220 V. c.a. 300 V. c.c.
Test voltage: 3 kV AC (<= 0.50 mmq), 5 kV AC (> 0.50 mmq)
Flame resistance: DIN 72551 Part 5, 7.Z8220, Par. 3.7
Bending radius: >= 6 x D (fixed)
Suitable for indoor use
Suitable for fixed installation
Resistance to chemical agents: DIN 72551 Part 5, ISO 6722, 7.Z8220 Par. 3.8
Resistance to diesel and gasoline: ISO 6722, 7.Z8220 Par. 3.8
Resistance to engine oil: ISO 6722 (ISO 1817 oil No. 3), 7.Z8220, Par. 3.8 (Class O1 oil)
Scheda Tecnica
Type de produit: FLRY-B Câble
Couleur: Vert
Diamètre externe: 2.90 mm
Voltage: 50V
Température de fonctionnement min.: -40°C
Température de fonctionnement max.: +105°C
Matériau d'isolation: PVC
Conducteur (matériel): Cuivre rouge
Section de câble mmq: 2.50 mmq
Nombre de brins: 50
Blindage: Non
Test de tension: 5000V
Type d'emploi: Secteur Automobile
Résistance du conducteur: <= 7.6 Ohm/Km
Caractéristiques
- MarqueERREBI GROUP
- CouleurVert
- Section2.5 mm²
- Poids26.4 g
- Quantité par pack1
- Longueur du câble électrique1 m
- MatièresPVC
- Tension électrique50 V
- Type de câble électriqueUnipolaire
- Réf. ManoManoME87400356
- MMID834212217863
- Réf. fabricantRBCVFLRYB2.5VR
Questions fréquentes
Quelle est la résistance du conducteur de ce câble ?
La résistance du conducteur de ce câble est inférieure ou égale à 7.6 Ohm/Km.
Quelle est la plage de température de fonctionnement de ce câble ?
La plage de température de fonctionnement de ce câble est de -40°C à +105°C.
Ce câble est-il adapté pour une installation fixe à l'intérieur ?
Oui, ce câble est conçu pour une utilisation en intérieur et est adapté pour une installation fixe.
Réponses générées par IA à partir des informations vendeur
Comment choisir des fils et câbles électriques ?
Les conseils de nos experts
Vous êtes ici :









