Câble Fil Unipolaire FLRY-B ISO 6722 Classe B Sec. 2,50 mmq Noir
Produit similaire livré par
Festool – Câble plug it H05 RN-F/4 – Longueur 4 m – Section 1,5 mm² – 4 fils – 203914
28,42 €
180
Vendu par Errebi shop
Ces articles peuvent vous intéresser !
Comparer à des articles similaires
Souvent achetés ensemble
Informations produit
Description
Code ErreBi: 22210
Vendu au mètre
APPLICATIONS
PVC insulated flexible single core cables that is intended for use on low voltage electrical installations, systems and components of road vehicles where the heat exposure is not continuous on cable surface The FR125 F5 cables are mainly intended for the wiring everywhere a frequent thermal loading, but continuously on cable, could be occurred.
CABLE STRUCTURE
1. Flexible electrolytic bare copper conductor: stranded multi-wire
2. Type B and class T2 105°C rated PVC insulation
Temperature range: -40 to 105°C (fixed)
Short-circuit temperature: 160°C
Rated voltage: 220 V. c.a. 300 V. c.c.
Test voltage: 3 kV AC (<= 0.50 mmq), 5 kV AC (> 0.50 mmq)
Flame resistance: DIN 72551 Part 5, 7.Z8220, Par. 3.7
Bending radius: >= 6 x D (fixed)
Suitable for indoor use
Suitable for fixed installation
Resistance to chemical agents: DIN 72551 Part 5, ISO 6722, 7.Z8220 Par. 3.8
Resistance to diesel and gasoline: ISO 6722, 7.Z8220 Par. 3.8
Resistance to engine oil: ISO 6722 (ISO 1817 oil No. 3), 7.Z8220, Par. 3.8 (Class O1 oil)
Scheda Tecnica
Type de produit: FLRY-B Câble
Couleur: Noir
Diamètre externe: 2.90 mm
Voltage: 50V
Température de fonctionnement min.: -40°C
Température de fonctionnement max.: +105°C
Matériau d'isolation: PVC
Conducteur (matériel): Cuivre rouge
Section de câble mmq: 2.50 mmq
Blindage: Non
Test de tension: 5000V
Type d'emploi: Secteur Automobile
Résistance du conducteur: <= 7.6 Ohm/Km
Vendu au mètre
APPLICATIONS
PVC insulated flexible single core cables that is intended for use on low voltage electrical installations, systems and components of road vehicles where the heat exposure is not continuous on cable surface The FR125 F5 cables are mainly intended for the wiring everywhere a frequent thermal loading, but continuously on cable, could be occurred.
CABLE STRUCTURE
1. Flexible electrolytic bare copper conductor: stranded multi-wire
2. Type B and class T2 105°C rated PVC insulation
Temperature range: -40 to 105°C (fixed)
Short-circuit temperature: 160°C
Rated voltage: 220 V. c.a. 300 V. c.c.
Test voltage: 3 kV AC (<= 0.50 mmq), 5 kV AC (> 0.50 mmq)
Flame resistance: DIN 72551 Part 5, 7.Z8220, Par. 3.7
Bending radius: >= 6 x D (fixed)
Suitable for indoor use
Suitable for fixed installation
Resistance to chemical agents: DIN 72551 Part 5, ISO 6722, 7.Z8220 Par. 3.8
Resistance to diesel and gasoline: ISO 6722, 7.Z8220 Par. 3.8
Resistance to engine oil: ISO 6722 (ISO 1817 oil No. 3), 7.Z8220, Par. 3.8 (Class O1 oil)
Scheda Tecnica
Type de produit: FLRY-B Câble
Couleur: Noir
Diamètre externe: 2.90 mm
Voltage: 50V
Température de fonctionnement min.: -40°C
Température de fonctionnement max.: +105°C
Matériau d'isolation: PVC
Conducteur (matériel): Cuivre rouge
Section de câble mmq: 2.50 mmq
Blindage: Non
Test de tension: 5000V
Type d'emploi: Secteur Automobile
Résistance du conducteur: <= 7.6 Ohm/Km
Caractéristiques
- MarqueERREBI GROUP
- Longueur1 m
- Poids26.4 g
- Tension électrique50 V
- MatièresPVC
Questions fréquentes
La plage de température de fonctionnement de ce câble est de -40°C à +105°C.
La résistance du conducteur de ce câble est inférieure ou égale à 7.6 Ohm/Km.
Oui, ce câble est conçu pour une utilisation en intérieur et est adapté pour une installation fixe.
Réponses générées par IA à partir des informations vendeur
Conseil par
Comment choisir des fils et câbles électriques ?
La section des fils électriques et des câbles est fonction de l’intensité, de l’installation et des équipements. Fil 3G1.5mm², fil monobrin, câblette, fil coaxial, connectique RJ45 ou fil hifi, la famille est nombreuse ! Pour ne plus confondre la phase, le neutre et la terre : suivez le guide !
Vous êtes ici :