Câble Extraflex 2,50 mm conducteur 24x0,20 mm Noir
Informations produit
Description
Code ErreBi: 30067
Vendu au mètre
Prix au 2 mètres
correspond à 2 mètres
Exemple: Si vous achetez 3 quantités, vous recevrez une pièce unique de 6 mètres
APPLICATIONS
These cables are suggested whereas flame-resistance is requested together with absence of smoke or toxic halogen fumes during the development of fire, they are suitable for indoor general wiring in public areas, for example as supply lead within cinemas, hospital or airport projects. As power or control cables for installation where fire, smoke emission and toxic fumes create a real danger for public safety. For temporary occasional outdoor use, also in places where vertical water drops fall is likely.
Temperature range: +5 to +70°C, -20 to +70°C (fixed installation)
Short-circuit temperature: 160°C
Rated voltage: 300/500 V
Test voltage: 2500 V
Flame resistance: IEC 60332-1-2
Halogen-free: EN 50525-1, EN 50267-2-2, EN 50267-2-1, EN 60884-2
Suitable for indoor use
Suitable for fixed installation
Bending radius: >= 10 x D (fixed installation)
Scheda Tecnica
Type de produit: Câble Extra-Flex
Couleur: Noir
Voltage: 500V
Température de fonctionnement min.: -20°C
Température de fonctionnement max.: +70°C
Conducteur (matériel): Cuivre rouge
Section de câble mmq: 2.50 mm
Nombre de brins: 24
Taille des brins: 0,20 mm
Test de tension: 2500V
Type d'emploi: Câblage Interne
Vendu au mètre
Prix au 2 mètres
correspond à 2 mètres
Exemple: Si vous achetez 3 quantités, vous recevrez une pièce unique de 6 mètres
APPLICATIONS
These cables are suggested whereas flame-resistance is requested together with absence of smoke or toxic halogen fumes during the development of fire, they are suitable for indoor general wiring in public areas, for example as supply lead within cinemas, hospital or airport projects. As power or control cables for installation where fire, smoke emission and toxic fumes create a real danger for public safety. For temporary occasional outdoor use, also in places where vertical water drops fall is likely.
Temperature range: +5 to +70°C, -20 to +70°C (fixed installation)
Short-circuit temperature: 160°C
Rated voltage: 300/500 V
Test voltage: 2500 V
Flame resistance: IEC 60332-1-2
Halogen-free: EN 50525-1, EN 50267-2-2, EN 50267-2-1, EN 60884-2
Suitable for indoor use
Suitable for fixed installation
Bending radius: >= 10 x D (fixed installation)
Scheda Tecnica
Type de produit: Câble Extra-Flex
Couleur: Noir
Voltage: 500V
Température de fonctionnement min.: -20°C
Température de fonctionnement max.: +70°C
Conducteur (matériel): Cuivre rouge
Section de câble mmq: 2.50 mm
Nombre de brins: 24
Taille des brins: 0,20 mm
Test de tension: 2500V
Type d'emploi: Câblage Interne
Caractéristiques
- Longueur2 m
- Tension électrique500 V
- MatièresCuivre
- CouleurNoir
- Section2.5 mm²
Questions fréquentes
Ce câble est conçu pour une utilisation intérieure et peut être utilisé temporairement en extérieur, mais il n'est pas adapté pour une installation permanente en extérieur.
En cas de court-circuit, ce câble peut supporter une température maximale de 160°C.
Le rayon de courbure minimal pour une installation fixe est égal ou supérieur à 10 fois le diamètre du câble.
Réponses générées par IA à partir des informations vendeur
Conseil par
Comment choisir des fils et câbles électriques ?
La section des fils électriques et des câbles est fonction de l’intensité, de l’installation et des équipements. Fil 3G1.5mm², fil monobrin, câblette, fil coaxial, connectique RJ45 ou fil hifi, la famille est nombreuse ! Pour ne plus confondre la phase, le neutre et la terre : suivez le guide !
Vous êtes ici :