Informations produit

Description

1、High Frequency Fast On Off: Realize the circuit's high frequency fast and frequent on off. No noise is generated during the on off process.

2、Stable Working: The module works without electric sparks, works stably without electromagnetic interference.

3、Long Service Life: Delay relay module can replace the electromagnetic relay, and the service life is longer than that of the common electromagnetic relay.

4、Wide Range Of Applications: Relay module often used to control motors, LED light strips, DC motors, micro water pumps, solenoid valves, etc.

5、Adjustable Time Range: The module can be adjusted at any time from 0.01 second to 999 minutes, and the input voltage is DC 7~24V universal.Item Type: Trigger Cycle Timer Delay Switch

Product Model: YF-11

Application: Can control solenoid valves, water pumps, motors, light strips, etc. to run freely

Input Voltage: DC 7~24V universal

Output Power: DC load within 10A can be controlled

Time Range: 0.01 second to 999 minutes, any time adjustableWiring Port Description:

1. DC+: Input the positive pole of the DC power supply

2. DC-: Input the negative pole of the DC power supply

3. IN+: Positive signal input terminal

4. IN-: Negative signal input terminal

5. OUT+: Output positive

6. OUT-: Output negativeButton Trigger: (Positive trigger: DC- and in- short circuited, DC+ and IN+ are connected to the button)

Or: (Negative trigger: DC+ and in+ short circuited, DC- and IN- are connected to the button)Function List:

P-11: Inching (start signal output, output stop when signal disappears)

P-12: Self locking (start signal output once, stop signal output again)

P-13: Give the signal, the output starts and stops automatically for A second; the trigger is invalid during the delay period

P-14: Give the signal, the output will start and stop automatically for A second; trigger to re-timing during the delay period

P-15: Give the signal, the output will start and stop automatically for A second; during the delay period, the superposition timer will be triggered

P-16: Gives the signal, the output starts and stops automatically for A second; reset is triggered during the delay period

P-17: Give the signal, the output starts, the input signal is disconnected, the power is turned off after the start of timing A second, and the signal is kept output during the delay period, and the timing stops

P-18: After power on, the output will start, and the power will be turned off after a delay of A seconds; until the next power on

P-21: Give the signal, after a delay of A seconds, the output will start

P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops

P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops

P-24: There is a signal, the output will start after A second, and the output will stop after the signal disappears for more than A second

P-25: When there is a signal, the output will start after more than A second, and the output will stop after more than A second when there is a signal

P-26: When there is a signal, the output will stop after A second after the start, and the output will stop after A second after the signal disappears.

P-27: Detection of a pulse signal, the output stops; no pulse signal, more than A second output start; (the signal continues or the signal disappears are regarded as no pulse signal)

P-28: After power on, after a delay of A second, the output starts until the power is off

P-31: After power on, the output starts for A second, stops for B second, infinite loop; power off stops

P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop

P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop

P-34: After power on, after a delay of A second, the output will start, and it will stop after closing B seconds

P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull in for B seconds

P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped.

P-37: When there is a signal, the output starts and stops automatically for A seconds, and then counts for B seconds after it stops. The signal trigger is invalid within the time A+B.

P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops

P-41: No action with signal; trigger when signal disappears; disconnect after output start delay A time

P-42: The signal disappears, after a delay of time A, the output starts; working time B ends

P-43: The signal disappears, after the time A exceeds, the output starts; the working time B ends

P-44: After power on, the output will start A time, stop B time; cycle C times and automatically stop.

P-45: No action when energized, after signal is given; output starts A time, stops B time; cycles C times and automatically stops; Give signal again, execute again

P-46: After giving the signal more than A times, the output will start; keep the output; stop when the power is off

P-47: After giving the signal more than A times, the output starts and stops for B seconds

P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B secondsButton Setting Instructions: power on display "----" means entering the standby state;

Press K1 for the first time, (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjustment main mode, K3K4 adjustment function

Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit)

Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)

Press K1 for the fourth time, the display "----" means entering the standby state

Press K4 in standby mode to permanently turn off/on the display and switch to low power consumption modeDecimal Point Time Unit Description:

X.XX The decimal point is in the hundred, and the timing range: 0.01 seconds to 9.99 seconds

XX.X The decimal point is in ten's place, timing range: 0.1 second to 99.9 seconds

XXX has no decimal point, timing range: 1 second to 999 seconds

XXX. The decimal point is in the ones place, timing range: 1 minute to 999 minutes1 x Trigger Cycle Timer Delay Switch

Caractéristiques

  • Marque
    SABE
  • Type d'affichage
    Digital
  • Réf. ManoMano
    ME236969912
  • MMID
    148905270607
  • Réf. fabricant
    SABE0812-FX14694
  • EAN
    7772992927537
Comment choisir son programmateur ou sa minuterie d'arrosage
Conseils

Comment choisir son programmateur ou sa minuterie d'arrosage

Voir la fiche conseil
Vous êtes ici :
Le spécialiste français du bricolage, maison, jardin

Le spécialiste français du bricolage, maison, jardin

Livraison et retours gratuits pendant 100 jours avec ManoExpress. ,[object Object]

Livraison et retours gratuits pendant 100 jours avec ManoExpress. En savoir plus

Paiement jusqu'à 12x par carte bancaire avec Alma. ,[object Object]

Paiement jusqu'à 12x par carte bancaire avec Alma. En savoir plus

Plus de 7 millions de clients pros et particuliers

Plus de 7 millions de clients pros et particuliers