Aller au contenu principal
1/4

Battery Charge Discharge Module Integrated Board Voltmeter Undervoltage Overvoltage Protection

(25,99€/pc)

Vous achetez pour votre entreprise ?

Tarifs négociés HT jusqu'à -20%

Produit similaire livré par
Régulateur solaire 30A 12/24V MPPT 100/30 – Détection automatique tension – Protection surchauffe – 1 entrée panneaux et batteries – Victron Energy
Régulateur solaire 30A 12/24V MPPT 100/30 – Détection automatique tension – Protection surchauffe – 1 entrée panneaux et batteries – Victron Energy
99,00 €
17
Vendu par MixHome

Ces articles peuvent vous intéresser !

SmartSolar Victron MPPT 75v /10AVICTRON
11 options

SmartSolar Victron MPPT 75v /10A

68
SmartSolar Victron MPPT 100/15VICTRON
11 options

SmartSolar Victron MPPT 100/15

68
SmartSolar MPPT 250/70-Tr VE.CanVICTRON
11 options

SmartSolar MPPT 250/70-Tr VE.Can

68

Comparer à des articles similaires

Informations produit

Description

1. An additional signal output. When the relay conduction condition is met, the module will output high level to control other devices. 2. With serial port communication function, the working status of the relay can be monitored in real time through the serial port. 3. Charge and discharge time can be set, and the battery charging board will automatically power off after setting. 4. There is a key emergency stop function (STOP key). With reverse connection protection, the reverse connection will not burn. 5. This battery charging module is designed for the batteries below 60V, and the error in voltage measuring is less than 0.1V. Specification: Item Type: Battery Charge and Discharge Module Product Material: Printed Circuit Board Product Parameters: 1: Power supply voltage: DC6--40V; Voltage Detection Range: DC 0--60V; Suitable for various batteries below 60V; Voltage Test Error: ±0.1V; 2: Charge and discharge time (OP) range: 0-999 Minutes. How to Use: 1. First determine the working mode of the relay; 2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default U-1 mode), and then enter the main interface,) "Long press the SET button for 2 seconds and then release” to enter the mode selection interface, and select the mode (U-1~U-6) by short pressing the UP and DOWN buttons; 3. After selecting the mode (such as U-1), short press the SET button to set the corresponding parameters. At this time, the parameters to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP conduction time), and press UP, DOWN to adjust the parameter value, supports long press (rapid increase or decrease) and short press (increase or decrease by 1 unit); short press the SET key to set the next parameter of the current mode, the process is the same as above; 4. After setting the parameters of the selected mode, press and hold the SET button for 2 seconds and then release it. The currently set mode will flash, and then return to the main interface. The parameter setting is successful, very simple 5. On the main interface, short press the DOWN button to switch between voltage and time, which is very simple. Mode Selection Interface: Long press the SET button to enter, after the setting is completed, long press the SET button to exit and return to the main interface, very simple Operating Mode: Voltage Upper Limit: UL1, Voltage Lower Limit: nL1, voltage upper limit must be greater than voltage lower limit (UL1>nL1) U-1: Charging Measurement: When the measured voltage is lower than the lower limit voltage, the relay is closed, and higher than the upper limit voltage, the relay is disconnected; U-2: Charging Measurement Time Control: Set the charging time (OP); when the measured voltage is lower than the lower limit voltage, the relay is closed, and the OP time starts to count down after the pull-in. When the time is up, the relay is disconnected; when the voltage is higher than the upper limit voltage, the relay disconnect. U-3: Discharge Detection: When the measured voltage is lower than the lower limit voltage, the relay is disconnected, and when the measured voltage is higher than the upper limit voltage, the relay is closed; U-4: Discharge Detection Time Control: Set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay is closed, and the OP time starts to count down after the pull-in. When the time is up, the relay is disconnected; when the measured voltage is lower than the lower limit Voltage, the relay is off; U-5: Closed in the Interval: When the measured voltage is between the upper limit and the lower limit, the relay is closed, otherwise it is disconnected; U-6: Pull-in Outside the Interval: When the measured voltage is lower than the lower limit voltage or higher than the upper limit voltage, the relay is pulled in, and the relay is disconnected in other cases;. Package List: 1 x Battery Charge Discharge Module

Caractéristiques

  • Marque
    MIXHOME
  • Matières
    Plastique
  • Réf. ManoMano
    ME265626341
  • MMID
    673854049955
  • Réf. fabricant
    MI1009-GM17081
  • EAN
    7794058119793
Vous êtes ici :
Le spécialiste français du bricolage, maison, jardin

Le spécialiste français du bricolage, maison, jardin

Livraison et retours gratuits pendant 100 jours avec ManoExpress. ,[object Object]

Livraison et retours gratuits pendant 100 jours avec ManoExpress. En savoir plus

Paiement jusqu'à 12x par carte bancaire avec Alma. ,[object Object]

Paiement jusqu'à 12x par carte bancaire avec Alma. En savoir plus

Plus de 7 millions de clients pros et particuliers

Plus de 7 millions de clients pros et particuliers